Skip to content

Commit 10a9788

Browse files
committed
Review
1 parent 1fe9495 commit 10a9788

File tree

2 files changed

+12
-9
lines changed

2 files changed

+12
-9
lines changed

connector/doc/Peak_Communications_RCU_H100.md

+10-9
Original file line numberDiff line numberDiff line change
@@ -6,7 +6,7 @@ uid: Connector_help_Peak_Communications_RCU_H100
66

77
The purpose of this connector is to manage and monitor the Peak Communications RCU H100 redundancy switching system. This system provides control over redundant units and ensures operational continuity by managing redundancy modes, unit statuses, and fault conditions.
88

9-
The Peak Communications RCU H100 operates through a serial-based interface and supports both manual and automated operations for redundancy switching. It facilitates monitoring and control of connected units via a set of discrete commands and responses, allowing for management of system modes and fault monitoring.
9+
The Peak Communications RCU H100 operates through a serial-based interface and supports both manual and automated operations for redundancy switching. It facilitates monitoring and control of connected units via a set of discrete commands and responses, allowing the management of system modes and monitoring of faults.
1010

1111
## About
1212

@@ -26,7 +26,7 @@ The Peak Communications RCU H100 operates through a serial-based interface and s
2626

2727
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
2828
| ------- | --------------- | ------------------- | ----------------- | ------------------- |
29-
| 1.0.0.x | No | Yes | - | |
29+
| 1.0.0.x | No | Yes | - | - |
3030

3131
## Configuration
3232

@@ -37,9 +37,10 @@ The Peak Communications RCU H100 operates through a serial-based interface and s
3737
This connector uses a serial connection and requires the following input during element creation:
3838

3939
SERIAL CONNECTION:
40-
- **Type of port:** TCP/IP
40+
41+
- **Type of port**: TCP/IP
4142
- **IP port**: 8004
42-
- **Bus address**: [The bus address of the device. (default: *32*)]
43+
- **Bus address**: The bus address of the device (default: *32*).
4344

4445
### Web Interface
4546

@@ -48,15 +49,15 @@ The web interface is only accessible when the client machine has network access
4849
## How to use
4950

5051
### Monitoring and Management
51-
52+
5253
The Peak Communications RCU H100 connector enables monitoring and management of redundancy settings, fault statuses, and operational modes. Key features include:
5354

54-
- **Fault Monitoring Page:** Provides a detailed view of faults, including power supply faults, environmental faults, and general hardware issues.
55-
- **Unit Status Page:** Displays real-time information about connected units, such as validity, online status, and CAN Bus connection status.
56-
- **General Page:** Offers system-wide information, including unit type, serial number, operational status, and redundancy mode.
55+
- **Fault Monitoring page**: Provides a detailed view of faults, including power supply faults, environmental faults, and general hardware issues.
56+
- **Unit Status page**: Displays real-time information about connected units, such as the validity, online status, and CAN Bus connection status.
57+
- **General page**: Offers system-wide information, including the unit type, serial number, operational status, and redundancy mode.
5758

5859
To monitor communication between the element and the device, use the Stream Viewer tool in DataMiner:
5960

6061
1. Right-click the element in the Surveyor.
6162
1. Select **View** > **Stream Viewer**.
62-
1. For healthy elements, you should see groups 1-4 for polling the data, and groups 5-6 for write commands
63+
1. For healthy elements, you should see groups 1-4 for polling the data, and groups 5-6 for write commands.

connector/toc.yml

+2
Original file line numberDiff line numberDiff line change
@@ -6843,6 +6843,8 @@
68436843
topicUid: Connector_help_Peak_Communications_PBU137
68446844
- name: Peak Communications PTR50
68456845
topicUid: Connector_help_Peak_Communications_PTR50
6846+
- name: Peak Communications RCU H100
6847+
topicUid: Connector_help_Peak_Communications_RCU_H100
68466848
- name: Peak Communications RCU100 SNMP
68476849
topicUid: Connector_help_Peak_Communications_RCU100_SNMP
68486850
- name: Peak Communications RCUH200

0 commit comments

Comments
 (0)