Skip to content

Commit a2c6ab4

Browse files
committed
Minor changes
1 parent 7079846 commit a2c6ab4

2 files changed

+6
-4
lines changed

connector/doc/Imagine_Communications_Platinum_Router.md

+4-2
Original file line numberDiff line numberDiff line change
@@ -4,7 +4,7 @@ uid: Connector_help_Imagine_Communications_Platinum_Router
44

55
# Imagine Communications Platinum Router
66

7-
This is a serial connector that is used to monitor and control the device **Imagine Communications Platinum Router.**
7+
This is a serial connector that is used to monitor and control the device **Imagine Communications Platinum Router**.
88

99
A platinum router is a matrix that can switch different types of sources (audio/video). The matrix can also be divided into several "virtual" matrixes, which each create a new level.
1010

@@ -78,6 +78,7 @@ On this page, you can view the status of the device matrix, and make changes to
7878
### Table View Page (version 1.1.0.3 onwards)
7979

8080
On this page, you can view a table representation of the matrix, and you can also set a crosspoint or disconnect it.
81+
8182
This is only available if the appropriate setting is configured on the **Configuration Page**.
8283

8384
### Configuration Page
@@ -98,6 +99,7 @@ On this page, you can view the status of the device matrix, and make changes to
9899
### Table View Page
99100

100101
On this page, you can view a table representation of the matrix, and you can also set a crosspoint or disconnect it.
102+
101103
This is only available if the appropriate setting is configured on the **Configuration Page**.
102104

103105
### Configuration Page
@@ -125,7 +127,7 @@ For inputs to be shown, you must enable the **Poll State** of the outputs on the
125127

126128
- Once the element has been created, the connector shows the connected crosspoints on the configured level. You can change the connected input for an output by clicking the new input. The Platinum Router will then automatically disconnect the originally connected input in order to connect the new input. This means that the connector will not send a disconnect command. It is currently not possible to disconnect a connected input, so the connector will never send a disconnect command. All communication happens through the LRC (Logical Router Control) protocol, which also sends notifications when a change occurs, so that changes are updated in real time.
127129
- All sets are (currently) done ONLY on the level that is being monitored.
128-
- It is possible to hide some inputs and outputs from the matrix. To do so, go to the **Configuration** page and set the **Matrix Resize Method** to *Manual.* Then set the **Number of Inputs Visible** to the number you want to see. The same applies for the outputs. When you do this, only the first chosen number of inputs and outputs will be visible in the matrix.
130+
- It is possible to hide some inputs and outputs from the matrix. To do so, go to the **Configuration** page and set the **Matrix Resize Method** to *Manual*. Then set the **Number of Inputs Visible** to the number you want to see. The same applies for the outputs. When you do this, only the first chosen number of inputs and outputs will be visible in the matrix.
129131
- The maximum number of inputs and outputs is 640.
130132
- When you set the **Matrix Resize Method** to *Automatic*, the connector will query the dimensions of the matrix and show only the first N and M inputs and outputs.
131133

connector/doc/Imagine_Communications_Platinum_VX_CQ_Router.md

+2-2
Original file line numberDiff line numberDiff line change
@@ -4,7 +4,7 @@ uid: Connector_help_Imagine_Communications_Platinum_VX_CQ_Router
44

55
# Imagine Communications Platinum Router VX CQ Router
66

7-
This is an SNMP connector that is used to monitor and control the device **Imagine Communications Platinum VX CQ.**
7+
This is an SNMP connector that is used to monitor and control the device **Imagine Communications Platinum VX CQ**.
88

99
A platinum router is a matrix that can switch different types of sources (audio/video). The matrix can also be divided into several "virtual" matrixes, which each create a new level.
1010

@@ -28,7 +28,7 @@ This connector requires **DataMiner version 8.5.3** or higher.
2828

2929
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
3030
|---------|-----------------|---------------------|-------------------|---------------------|
31-
| 1.0.0.x | Yes | Yes | - | - |
31+
| 1.0.0.x | Yes | Yes | - | - |
3232

3333
## Configuration
3434

0 commit comments

Comments
 (0)