You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
> This connector is deprecated. [Bridge Technologies VB Probe Series](xref:Connector_help_Bridge_Technologies_VB_Probe_Series) should be used instead.
9
+
7
10
The VB220 IP-PROBE is a monitoring platform for applications in networks where digital video is carried across an IP infrastructure. It is built specifically for high-end industry needs and can monitor both pure IPTV networks and hybrid networks with IP transport cores, such as digital cable and terrestrial networks.
8
11
9
12
## About
@@ -15,24 +18,25 @@ VB280 is supported in a separate version of the connector.
| 3.2.0.x | Obsolete -\> See 3.3.1.x.**Ethernet Streams Table** has a different primary key (decremented by 1) -\> Historical data for this table will be lost.**PID Info Polling** should be disabled if firmware \< 5.3. **RDP Version** should be set to *Version 1* if firmware \< 5.2; otherwise, it should be set to *Version 2*. **Ethernet Multicast Version** should be double-checked. | No | Yes |
26
-
| 3.2.1.x | Obsolete -\> See 3.3.0.x.Added support for EII pidInfo call -\> no impact expected | Yes | Yes |
27
-
| 3.3.0.x | Obsolete -\> See 3.3.1.x. OTT Streams Table renamed to OTT Profiles -\> minor impact expected. | Yes | Yes |
28
-
| 3.3.1.x | Obsolete -\> See 3.3.2.x. **PID Info Polling** should be disabled if firmware \< 5.3. **RDP Version** should be set to *Version 1* if firmware \< 5.2; otherwise, it should be set to *Version 2*. **Ethernet Multicast Version** should be double-checked. | Yes | Yes |
29
-
| 3.3.2.x | Obsolete -\> See 3.3.3.x. Standalone "CPU Core 1-2 Usage" parameters were replaced by a table with all CPU cores. | Yes | Yes |
30
-
|**3.3.3.x**|**Main Range** Fixed PKs on Streams tables. |**Yes**|**Yes**|
31
-
| 4.1.0.x | Obsolete -\> See 4.3.0.x. | No | Yes |
32
-
| 4.2.0.x | Obsolete -\> See 4.3.0.x. | No | Yes |
33
-
| 4.3.0.x | Specific version Only to be used if very accurate timing on alarms (history sets) is required. | No | Yes |
34
-
| 5.0.0.x | Obsolete |||
35
-
| 6.0.0.x | Obsolete Based on 3.2.0.X, but display keys use the naming options of before 3.2.0.67. | No | Yes |
| 3.2.0.x | Obsolete -\> See 3.3.1.x.<br>**Ethernet Streams Table** has a different primary key (decremented by 1) -\> Historical data for this table will be lost.<br>**PID Info Polling** should be disabled if firmware \< 5.3. <br>**RDP Version** should be set to *Version 1* if firmware \< 5.2; otherwise, it should be set to *Version 2*. <br>**Ethernet Multicast Version** should be double-checked. | No | Yes |
29
+
| 3.2.1.x | Obsolete -\> See 3.3.0.x.<br>Added support for EII pidInfo call -\> no impact expected. | Yes | Yes |
30
+
| 3.3.0.x | Obsolete -\> See 3.3.1.x.<br>OTT Streams Table renamed to OTT Profiles -\> minor impact expected. | Yes | Yes |
31
+
| 3.3.1.x | Obsolete -\> See 3.3.2.x.<br>**PID Info Polling** should be disabled if firmware \< 5.3.<br>**RDP Version** should be set to *Version 1* if firmware \< 5.2; otherwise, it should be set to *Version 2*.<br>**Ethernet Multicast Version** should be double-checked. | Yes | Yes |
32
+
| 3.3.2.x | Obsolete -\> See 3.3.3.x.<br>Standalone "CPU Core 1-2 Usage" parameters replaced with a table with all CPU cores. | Yes | Yes |
33
+
|**3.3.3.x**|**Last Main Range**<br>Fixed PKs on Streams tables.<br>**[Bridge Technologies VB Probe Series](xref:Connector_help_Bridge_Technologies_VB_Probe_Series) should be used instead.**|
34
+
|| Yes | Yes |
35
+
| 4.1.0.x | Obsolete -\> See 4.3.0.x. | No | Yes |
36
+
| 4.2.0.x | Obsolete -\> See 4.3.0.x. | No | Yes |
37
+
| 4.3.0.x | Specific version<br>Only to be used if very accurate timing on alarms (history sets) is required. | No | Yes |
38
+
| 5.0.0.x | Obsolete |||
39
+
| 6.0.0.x | Obsolete<br>Based on 3.2.0.X, but display keys use the naming options of before 3.2.0.67. | No | Yes |
0 commit comments