Skip to content

Commit 44024ca

Browse files
tcarmelveilleuxrestyled-commits
andauthoredSep 17, 2024
Remove all un-specified draft clusters from SDK (project-chip#35583)
* Start removing Binary Input * Remove Binary Input Basic cluster (not in spec) * Remove the rest of draft clusters * Remove leftover bits * Restyled by prettier-json * Restyled by prettier-markdown * Run zap_convert_all * Regen ZAP * Fix build * Kick restyle * remove dead file --------- Co-authored-by: Restyled.io <commits@restyled.io>
1 parent 669c200 commit 44024ca

File tree

152 files changed

+1093
-60683
lines changed

Some content is hidden

Large Commits have some content hidden by default. Use the searchbox below for content that may be hidden.

152 files changed

+1093
-60683
lines changed
 

‎.github/workflows/tests.yaml

-4
Original file line numberDiff line numberDiff line change
@@ -202,10 +202,6 @@ jobs:
202202
src/app/zap-templates/zcl/data-model/chip/window-covering.xml \
203203
src/app/zap-templates/zcl/data-model/chip/temperature-control-cluster.xml \
204204
src/app/zap-templates/zcl/data-model/chip/matter-devices.xml \
205-
src/app/zap-templates/zcl/data-model/draft/barrier-control-cluster.xml \
206-
src/app/zap-templates/zcl/data-model/draft/electrical-measurement-cluster.xml \
207-
src/app/zap-templates/zcl/data-model/draft/input-output-value-clusters.xml \
208-
src/app/zap-templates/zcl/data-model/draft/onoff-switch-configuration-cluster.xml \
209205
src/app/zap-templates/zcl/data-model/chip/resource-monitoring-cluster.xml \
210206
src/app/zap-templates/zcl/data-model/chip/sample-mei-cluster.xml \
211207
src/app/zap-templates/zcl/data-model/chip/electrical-energy-measurement-cluster.xml \

‎docs/zap_clusters.md

-4
Original file line numberDiff line numberDiff line change
@@ -15,9 +15,7 @@ Generally regenerate using one of:
1515
| 3 | 0x03 | Identify |
1616
| 4 | 0x04 | Groups |
1717
| 6 | 0x06 | OnOff |
18-
| 7 | 0x07 | OnOffSwitchConfiguration |
1918
| 8 | 0x08 | LevelControl |
20-
| 15 | 0x0F | BinaryInputBasic |
2119
| 28 | 0x1C | PulseWidthModulation |
2220
| 29 | 0x1D | Descriptor |
2321
| 30 | 0x1E | Binding |
@@ -91,7 +89,6 @@ Generally regenerate using one of:
9189
| 159 | 0x9F | DeviceEnergyManagementMode |
9290
| 257 | 0x101 | DoorLock |
9391
| 258 | 0x102 | WindowCovering |
94-
| 259 | 0x103 | BarrierControl |
9592
| 336 | 0x150 | ServiceArea |
9693
| 512 | 0x200 | PumpConfigurationAndControl |
9794
| 513 | 0x201 | Thermostat |
@@ -134,7 +131,6 @@ Generally regenerate using one of:
134131
| 1296 | 0x510 | ContentAppObserver |
135132
| 1872 | 0x750 | EcosystemInformation |
136133
| 1873 | 0x751 | CommissionerControl |
137-
| 2820 | 0xB04 | ElectricalMeasurement |
138134
| 4294048773 | 0xFFF1FC05 | UnitTesting |
139135
| 4294048774 | 0xFFF1FC06 | FaultInjection |
140136
| 4294048800 | 0xFFF1FC20 | SampleMei |

0 commit comments

Comments
 (0)
Please sign in to comment.