Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathInput_data_summer.m
167 lines (111 loc) · 4.35 KB
/
Input_data_summer.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
% Read data relative to the European Case study
clear all
% File containing data
filename='data_problem.xlsx';
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% Define problem data
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% Three dimensional system: 1 thermal equation,1 battery storage
load activation % w
% State and input bounds for the battery
Cap_b=60; %120; %kwh
p_rate=10; % Kw
leak_battery=0; %1/2000;
xlow=[-10, -1, -10];
xup=[40,Cap_b,40];
% 6 inputs
% 1) Electricty (Power) used by edHP, 2) cooling HP, 3) Battery discharge rate,
% 4) Battery charge rate, 5) Power bought from the grid 6) Power inject into the grid
ulow=[0, 0, 0, 0, 0, 0, 0, 0, 0, -30, 0,0,0];
% [ueH uCeH udch uch uB uS]
% Inputs upper bounds in kW
% [ueH uCeH udch uch uB uS]
% uup=[inf, inf, p_rate, p_rate, inf, inf, inf, inf, p_rate, p_rate, inf, inf];
%
uup=[7, 7, p_rate, p_rate, 30, 30, 7, 7, 30, 0, 100,100,100];
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% Retrieve parameters ofa 3 room building for a lumped model
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
UV=xlsread(filename,1,'B4'); % overall heat transfer coefficient, U (Average U-value) ( W/m^2 K)
UV=UV/1000; % convertin W in kW
A=xlsread(filename,1,'B3'); % Wall surface Area (m^2)
rhoAir=xlsread(filename,1,'B8'); % Air density (kg/ m^3)
B_V=xlsread(filename,1,'B6'); % Building Volume (m^3)
C_air=xlsread(filename,1,'B9'); % Air heat capacity (kJ/ kg/ K)
C_air=C_air/3600; % Converting kJ in kWh
n_ac=xlsread(filename,1,'B7'); % Air changes per hour (hr^(-1))
C_Build=xlsread(filename,1,'B10'); % Building Capacity (kj/ K)(Note kJ/C is equivalent to kj/K)
C_Build=C_Build/3600; % Converting kJ in kWh
AFl=xlsread(filename,1,'B2'); % Floor surface Area (m^2)
%Carbon_e=xlsread(filename,5,'B2:B722')'; % winter
Carbon_e=xlsread(filename,5,'B9266:B9986')'; % summer
%Ir=xlsread(filename,7,'C333125:D333485')'; % Hourly data winter
Ir=xlsread(filename,7,'C337757:C338117')'; % Summer
%Pr_elec=xlsread(filename,4,'B2:B1442')'; % (£/kWh) From 1/1/2018
Pr_elec=xlsread(filename,4,'B18530:B19970')'; % (£/kWh) From 13/7/2018
% External temperature
%T_ex_r=xlsread(filename,7,'B333125:B333485')'; % (^circ C) From 1/1/2018
T_ex_r=xlsread(filename,7,'B337757:B338117')'; % 13/7/2018
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% Carbon Emission half hourly data
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
T_carb=[0:1/2:360]; % Vector of times
Price_carbon=100; % in £/(ton CO2e)
Price_carbon= Price_carbon/1e+6; % converted in £/gr
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% Hourly data of Global horizontal irradiance (W/m^2)
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% Converting W to kW
Ir=Ir/1000;
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% Exogenous Inputs
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
%Desired vector of times associated to the external data
T_mex=[0:1/4:360];
% Interpolation values of Carbon emission
Carbon_em=interp1(T_carb,Carbon_e,T_mex,'linear'); % (£/kWh)
% Interpolation of radiance data
Ir=interp1([0:360],Ir,T_mex,'linear');
% Interpolation of ambient Temperature
T_ex=interp1([0:360],T_ex_r,T_mex,'linear');
% Notes
% To Convert kJ to Wh divide by 3.6
%
% Kelvin to celsius conversion [C] = [K]-273.15
%
% The COP for an electric driven heat pump at 7 \circ celsius is assumed equal to 3
%
% I assume that at 22 \circ celsius COP is 4
COP_init=3;
T_init=7;
COP_Ta=4;
Ta=22;
% coefficient of the COP for the heat pump accounting of a linear dependence with respect to
% the external temperature
m_COP=(COP_Ta-COP_init)/(Ta-T_init);
m_cop_cool=0.7; % COP of the cooling system
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% Batteries
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
dis_eff=1; %discharge efficiency
ch_eff=0.88; %charge efficiency
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% PVs
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% The prediction output is in KWp/m^2
theta1=xlsread(filename,3,'E4');
theta2=xlsread(filename,3,'E5');
theta3=xlsread(filename,3,'E6');
% Proportion of total area covered by PVs
PV_s_Ap=1;
% Proportion of total area covered by Thermal Solar
% TSo_Ap=1/2;
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% Ancillary service
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
r=0.1;
cost_slack=5;
T_w=[0:1/60:360];
% w=-1+rand(size(T_w));
save External_data Ir T_ex T_mex w
save case_study_sim