#include "Arduino.h"
#include "Growatt.h"
#include "Growatt305.h"
void init_growatt305(sProtocolDefinition_t& Protocol, Growatt& inverter) {
// definition of input registers
Protocol.InputRegisterCount = 12;
// address, value, size, name, multiplier, unit, frontend, plot
// FRAGMENT 1: BEGIN
Protocol.InputRegisters[P305_I_STATUS] = sGrowattModbusReg_t{
0, 0, SIZE_16BIT, F("InverterStatus"), 1, 1, NONE, true, false}; // #1
Protocol.InputRegisters[P305_DC_POWER] = sGrowattModbusReg_t{
1, 0, SIZE_32BIT, F("DcPower"), 0.1, 0.1, POWER_W, true, true}; // #2
Protocol.InputRegisters[P305_DC_VOLTAGE] = sGrowattModbusReg_t{
3, 0, SIZE_16BIT, F("DcVoltage"), 0.1, 0.1, VOLTAGE, true, false}; // #3
Protocol.InputRegisters[P305_DC_INPUT_CURRENT] = sGrowattModbusReg_t{
4, 0, SIZE_16BIT, F("DcInputCurrent"), 0.1, 0.1,
CURRENT, true, false}; // #4
Protocol.InputRegisters[P305_AC_FREQUENCY] = sGrowattModbusReg_t{
13, 0, SIZE_16BIT, F("AcFrequency"), 0.01, 0.01,
FREQUENCY, true, false}; // #5
Protocol.InputRegisters[P305_AC_VOLTAGE] = sGrowattModbusReg_t{
14, 0, SIZE_16BIT, F("AcVoltage"), 0.1, 0.1, VOLTAGE, true, false}; // #6
Protocol.InputRegisters[P305_AC_OUTPUT_CURRENT] = sGrowattModbusReg_t{
15, 0, SIZE_16BIT, F("AcOutputCurrent"), 0.1, 0.1,
CURRENT, true, false}; // #7
Protocol.InputRegisters[P305_AC_POWER] = sGrowattModbusReg_t{
16, 0, SIZE_32BIT, F("AcPower"), 0.1, 0.1, POWER_W, true, true}; // #8
Protocol.InputRegisters[P305_ENERGY_TODAY] = sGrowattModbusReg_t{
26, 0, SIZE_32BIT, F("EnergyToday"), 0.1, 0.1,
POWER_KWH, true, false}; // #9
Protocol.InputRegisters[P305_ENERGY_TOTAL] = sGrowattModbusReg_t{
28, 0, SIZE_32BIT, F("EnergyTotal"), 0.1, 0.1,
POWER_KWH, true, false}; // #10
Protocol.InputRegisters[P305_OPERATING_TIME] =
sGrowattModbusReg_t{30, 0, SIZE_32BIT, F("OperatingTime"), 0.5, 1,
SECONDS, true, false}; // #11
Protocol.InputRegisters[P305_TEMPERATURE] = sGrowattModbusReg_t{
32, 0, SIZE_16BIT, F("Temperature"), 0.1, 0.1,
TEMPERATURE, true, false}; // #12
Protocol.InputFragmentCount = 1;
Protocol.InputReadFragments[0] = sGrowattReadFragment_t{0, 33};
Protocol.HoldingRegisterCount = 0;
Protocol.HoldingFragmentCount = 0;
}