Notifications
You must be signed in to change notification settings - Fork 2.1k
/
Copy pathTest_TC_REFALM_2_2.yaml
207 lines (188 loc) · 6.29 KB
/
Test_TC_REFALM_2_2.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
# Copyright (c) 2023 Project CHIP Authors
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
name: 223.2.2. [TC-REFALM-2.2] Primary functionality with DUT as Server
PICS:
- REFALM.S
config:
nodeId: 0x12344321
cluster: "Refrigerator Alarm"
endpoint: 1
PIXIT.REFALM.AlarmThreshold:
type: int16u
defaultValue: 5
tests:
- label:
"Step 1: Commission DUT to TH (can be skipped if done in a preceding
test)"
cluster: "DelayCommands"
command: "WaitForCommissionee"
arguments:
values:
- name: "nodeId"
value: nodeId
- label: "Step 2: Ensure that the door on the DUT is closed"
verification: |
Ensure that the door on the DUT is closed
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_USER_PROMPT
arguments:
values:
- name: "message"
value: "Enter 'y' after success"
- name: "expectedValue"
value: "y"
- label: "Step 3:TH reads from the DUT the State attribute"
command: "readAttribute"
attribute: "State"
PICS: REFALM.S.A0002
response:
constraints:
type: bitmap32
hasMasksClear: [0x1]
- label: "Step 4: Manually open the door on the DUT"
verification: |
Manually open the door on the DUT
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_USER_PROMPT
arguments:
values:
- name: "message"
value: "Enter 'y' after success"
- name: "expectedValue"
value: "y"
- label: "Step 5: Wait for the time defined in PIXIT.REFALM.AlarmThreshold"
cluster: "DelayCommands"
command: "WaitForMs"
PICS: PICS_USER_PROMPT
arguments:
values:
- name: "ms"
value: PIXIT.REFALM.AlarmThreshold * 1000
- label: "Step 6: TH reads from the DUT the State attribute"
command: "readAttribute"
attribute: "State"
PICS: REFALM.S.A0002 && PICS_USER_PROMPT
response:
constraints:
type: bitmap32
hasMasksSet: [0x1]
- label: "Step 7: Ensure that the door on the DUT is closed"
verification: |
Ensure that the door on the DUT is closed
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_USER_PROMPT
arguments:
values:
- name: "message"
value: "Enter 'y' after success"
- name: "expectedValue"
value: "y"
- label: "Step 8: TH reads from the DUT the State attribute"
command: "readAttribute"
attribute: "State"
PICS: REFALM.S.A0002 PICS_USER_PROMPT
response:
constraints:
type: bitmap32
hasMasksClear: [0x1]
# Issue: https://github.com/project-chip/connectedhomeip/issues/28325
# Issue: https://github.com/project-chip/connectedhomeip/issues/27235
- label: "Step 9: TH sends Reset command to the DUT"
PICS: REFALM.S.C00.Rsp && PICS_USER_PROMPT
verification: |
Reset command is not implemeted in Chip-tool
cluster: "LogCommands"
command: "UserPrompt"
arguments:
values:
- name: "message"
value: "Enter 'y' after success"
- name: "expectedValue"
value: "y"
- label: "Step 10: TH sends ModifyEnabledAlarms command to the DUT"
PICS: REFALM.S.C01.Rsp && PICS_USER_PROMPT
verification: |
ModifyEnabledAlarms is not implemeted in Chip-tool
cluster: "LogCommands"
command: "UserPrompt"
arguments:
values:
- name: "message"
value: "Enter 'y' after success"
- name: "expectedValue"
value: "y"
- label: "Step 11: Set up subscription to the Notify event."
PICS: REFALM.S.E00 && REFALM.S.A0002
command: "subscribeEvent"
event: "Notify"
minInterval: 2
maxInterval: 10
- label: "Step 12a: Repeating step 4 Manually open the door on the DUT"
verification: |
Manually open the door on the DUT
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_USER_PROMPT
arguments:
values:
- name: "message"
value: "Enter 'y' after success"
- name: "expectedValue"
value: "y"
- label:
"Step 12b: Repeat step 5 Wait for the time defined in
PIXIT.REFALM.AlarmThreshold"
cluster: "DelayCommands"
command: "WaitForMs"
PICS: PICS_USER_PROMPT
arguments:
values:
- name: "ms"
value: PIXIT.REFALM.AlarmThreshold * 1000
- label:
"Step 12c: After step 5 (repeated), receive a Notify event with the
State attribute bit 0 set to 1."
command: "readAttribute"
attribute: "State"
PICS: REFALM.S.A0002 && PICS_USER_PROMPT
response:
constraints:
type: bitmap32
hasMasksSet: [0x1]
- label:
"Step 13a : Repeat step 7 Ensure that the door on the DUT is closed"
verification: |
Manually open the door on the DUT
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_USER_PROMPT
arguments:
values:
- name: "message"
value: "Enter 'y' after success"
- name: "expectedValue"
value: "y"
- label:
"Step 13b: Receive a Notify event with the State attribute bit 0 set
to 0"
command: "readAttribute"
attribute: "State"
PICS: REFALM.S.A0002 && PICS_USER_PROMPT
response:
constraints:
type: bitmap32
hasMasksClear: [0x1]