# Copyright (c) 2021 Project CHIP Authors
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
name: 7.2.2. [TC-TMP-2.2] Primary functionality with server as DUT
PICS:
- TMP.S
config:
nodeId: 0x12344321
cluster: "Temperature Measurement"
endpoint: 1
tests:
- label: "Step 1: Commission DUT to TH"
cluster: "DelayCommands"
command: "WaitForCommissionee"
arguments:
values:
- name: "nodeId"
value: nodeId
- label: "Step 2: TH reads MinMeasuredValue attribute from DUT"
PICS: TMP.S.A0001
command: "readAttribute"
attribute: "MinMeasuredValue"
response:
constraints:
type: int16s
minValue: -27315
maxValue: 32766
- label: "Step 3: TH reads MaxMeasuredValue attribute from DUT"
PICS: TMP.S.A0002
command: "readAttribute"
attribute: "MaxMeasuredValue"
response:
constraints:
type: int16s
minValue: -27314
maxValue: 32767
- label: "Step 4: TH reads MeasuredValue attribute from DUT"
PICS: TMP.S.A0000
command: "readAttribute"
attribute: "MeasuredValue"
response:
saveAs: valueBeforeChange
constraints:
type: int16s
minValue: -27314
maxValue: 32767
- label: "Step 5: Operate on device to change the temperature significantly"
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_USER_PROMPT && TMP.M.ManuallyControlled
arguments:
values:
- name: "message"
value: "Please enter 'y' for success"
- name: "expectedValue"
value: "y"
- label:
"Step 6: After a few seconds, TH reads MeasuredValue attribute from
DUT"
command: "readAttribute"
attribute: "MeasuredValue"
PICS: TMP.S.A0000 && TMP.M.ManuallyControlled
response:
constraints:
type: int16s
minValue: -27314
maxValue: 32767
notValue: valueBeforeChange