Notifications
You must be signed in to change notification settings - Fork 2.1k
/
Copy pathTest_TC_LVL_7_1.yaml
236 lines (213 loc) · 7.22 KB
/
Test_TC_LVL_7_1.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
# Copyright (c) 2021 Project CHIP Authors
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
# Auto-generated scripts for harness use only, please review before automation. The endpoints and cluster names are currently set to default
name:
22.6.2. [TC-LVL-7.1] Verification of MoveToClosestFrequency command (DUT as
Server)
PICS:
- LVL.S
- LVL.S.F02
config:
nodeId: 0x12344321
cluster: "Level Control"
endpoint: 1
RandomLevelValue:
type: int8u
defaultValue: 100
RandomFrequencyValue:
type: int16u
defaultValue: 30000
tests:
- label:
"Commission DUT to TH (can be skipped if done in a preceding test)."
cluster: "DelayCommands"
command: "WaitForCommissionee"
arguments:
values:
- name: "nodeId"
value: nodeId
#Adding below step resolve the issue https://github.com/CHIP-Specifications/chip-certification-tool/issues/499
- label:
"Precondition: write default value of OnOffTransitionTime attribute"
PICS: LVL.S.A0010
command: "writeAttribute"
attribute: "OnOffTransitionTime"
arguments:
value: 0
- label: "Step 0a: TH writes 0x00 to the Options attribute"
PICS: LVL.S.A000f
command: "writeAttribute"
attribute: "Options"
arguments:
value: 0
- label: "Step 0b: TH sends On command to DUT"
cluster: "On/Off"
PICS: OO.S.C01.Rsp
command: "On"
- label: "Step 1a: TH reads the MinLevel attribute from the DUT"
PICS: LVL.S.A0002
command: "readAttribute"
attribute: "MinLevel"
response:
saveAs: minLevelValue
constraints:
type: int8u
minValue: 0
maxValue: 254
- label: "Step 1b: TH reads the MaxLevel attribute from the DUT"
PICS: LVL.S.A0003
command: "readAttribute"
attribute: "MaxLevel"
response:
saveAs: maxLevelValue
constraints:
type: int8u
minValue: 0
maxValue: 254
- label:
"Step 1c: TH sends a MoveToLevel command to DUT, with the Level field
set to a value between the MinLevel and MaxLevel values (if present,
otherwise between 0x01 and 0xFE) and the TransitionTime field set to
0x0000 (move immediately)."
PICS: LVL.S.C00.Rsp
command: "MoveToLevel"
arguments:
values:
- name: "Level"
value: RandomLevelValue
- name: "TransitionTime"
value: 0
- name: "OptionsMask"
value: 0
- name: "OptionsOverride"
value: 0
- label: "Wait 100ms"
cluster: "DelayCommands"
command: "WaitForMs"
arguments:
values:
- name: "ms"
value: 100
- label: "Step 1d: TH reads CurrentLevel attribute from DUT"
PICS: LVL.S.C00.Rsp && LVL.S.A0000
command: "readAttribute"
attribute: "CurrentLevel"
response:
value: RandomLevelValue
- label: "Step 2a: TH reads the CurrentFrequency attribute."
PICS: LVL.S.A0004
command: "readAttribute"
attribute: "CurrentFrequency"
response:
saveAs: CurrentFrequencyValue
constraints:
type: int16u
minValue: 0
maxValue: 65535
- label: "Step 2b: TH reads the MinFrequency attribute."
PICS: LVL.S.A0005
command: "readAttribute"
attribute: "MinFrequency"
response:
saveAs: MinFrequencyValue
constraints:
type: int16u
minValue: 0
maxValue: 65535
- label:
"Step 2c: TH reads the MaxFrequency attribute and check, if fmax <
fmin, FAIL the test."
PICS: LVL.S.A0006
command: "readAttribute"
attribute: "MaxFrequency"
response:
saveAs: MaxFrequencyValue
constraints:
type: int16u
minValue: MinFrequencyValue
maxValue: 65535
- label:
"Step 2d: sanity check on values read in steps 2a..2c, if fc < fmin,
FAIL the test and fc > fmax, FAIL the test"
PICS: LVL.S.A0004
command: "readAttribute"
attribute: "CurrentFrequency"
response:
constraints:
type: int16u
minValue: MinFrequencyValue
maxValue: MaxFrequencyValue
- label:
"Step 3a: TH sends a MoveToClosestFrequency command to DUT, with the
frequency field set to a random value frand, chosen such that: fmin <
frand < fmax"
PICS: LVL.S.C08.Rsp
command: "MoveToClosestFrequency"
arguments:
values:
- name: "Frequency"
value: RandomFrequencyValue
- label: "Wait 100ms"
cluster: "DelayCommands"
command: "WaitForMs"
arguments:
values:
- name: "ms"
value: 100
- label: "Step 3b: TH reads the CurrentFrequency attribute."
PICS: LVL.S.C08.Rsp && LVL.S.A0004
command: "readAttribute"
attribute: "CurrentFrequency"
response:
value: RandomFrequencyValue
- label:
"Step 4a: TH sends a MoveToClosestFrequency command to DUT, with the
frequency field set to fmax + 1"
PICS: LVL.S.C08.Rsp && PICS_USER_PROMPT
verification: |
Frequency feature is Optional & is not verifiable at this moment. Please skip this step
cluster: "LogCommands"
command: "UserPrompt"
arguments:
values:
- name: "message"
value: "Please enter 'y' for success"
- name: "expectedValue"
value: "y"
- label: "Step 4b: TH reads the CurrentFrequency attribute."
PICS: LVL.S.C08.Rsp && LVL.S.A0004 && PICS_USER_PROMPT
command: "readAttribute"
attribute: "CurrentFrequency"
response:
value: RandomFrequencyValue
- label:
"Step 5a: TH sends a MoveToClosestFrequency command to DUT, with the
frequency field set to fmin - 1"
PICS: LVL.S.C08.Rsp && PICS_USER_PROMPT
verification: |
Frequency feature is Optional & is not verifiable at this moment. Please skip this step
cluster: "LogCommands"
command: "UserPrompt"
arguments:
values:
- name: "message"
value: "Please enter 'y' for success"
- name: "expectedValue"
value: "y"
- label: "Step 5b: TH reads the CurrentFrequency attribute."
PICS: LVL.S.C08.Rsp && LVL.S.A0004 && PICS_USER_PROMPT
command: "readAttribute"
attribute: "CurrentFrequency"
response:
value: RandomFrequencyValue