1
+ <?xml version =" 1.0" ?>
2
+ <!--
3
+ Copyright (C) Connectivity Standards Alliance (2021). All rights reserved.
4
+ The information within this document is the property of the Connectivity
5
+ Standards Alliance and its use and disclosure are restricted, except as
6
+ expressly set forth herein.
7
+
8
+ Connectivity Standards Alliance hereby grants you a fully-paid, non-exclusive,
9
+ nontransferable, worldwide, limited and revocable license (without the right to
10
+ sublicense), under Connectivity Standards Alliance's applicable copyright
11
+ rights, to view, download, save, reproduce and use the document solely for your
12
+ own internal purposes and in accordance with the terms of the license set forth
13
+ herein. This license does not authorize you to, and you expressly warrant that
14
+ you shall not: (a) permit others (outside your organization) to use this
15
+ document; (b) post or publish this document; (c) modify, adapt, translate, or
16
+ otherwise change this document in any manner or create any derivative work
17
+ based on this document; (d) remove or modify any notice or label on this
18
+ document, including this Copyright Notice, License and Disclaimer. The
19
+ Connectivity Standards Alliance does not grant you any license hereunder other
20
+ than as expressly stated herein.
21
+
22
+ Elements of this document may be subject to third party intellectual property
23
+ rights, including without limitation, patent, copyright or trademark rights,
24
+ and any such third party may or may not be a member of the Connectivity
25
+ Standards Alliance. Connectivity Standards Alliance members grant other
26
+ Connectivity Standards Alliance members certain intellectual property rights as
27
+ set forth in the Connectivity Standards Alliance IPR Policy. Connectivity
28
+ Standards Alliance members do not grant you any rights under this license. The
29
+ Connectivity Standards Alliance is not responsible for, and shall not be held
30
+ responsible in any manner for, identifying or failing to identify any or all
31
+ such third party intellectual property rights. Please visit www.csa-iot.org for
32
+ more information on how to become a member of the Connectivity Standards
33
+ Alliance.
34
+
35
+ This document and the information contained herein are provided on an “AS IS”
36
+ basis and the Connectivity Standards Alliance DISCLAIMS ALL WARRANTIES EXPRESS
37
+ OR IMPLIED, INCLUDING BUT NOT LIMITED TO (A) ANY WARRANTY THAT THE USE OF THE
38
+ INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OF THIRD PARTIES (INCLUDING
39
+ WITHOUT LIMITATION ANY INTELLECTUAL PROPERTY RIGHTS INCLUDING PATENT, COPYRIGHT
40
+ OR TRADEMARK RIGHTS); OR (B) ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS
41
+ FOR A PARTICULAR PURPOSE, TITLE OR NONINFRINGEMENT. IN NO EVENT WILL THE
42
+ CONNECTIVITY STANDARDS ALLIANCE BE LIABLE FOR ANY LOSS OF PROFITS, LOSS OF
43
+ BUSINESS, LOSS OF USE OF DATA, INTERRUPTION OF BUSINESS, OR FOR ANY OTHER
44
+ DIRECT, INDIRECT, SPECIAL OR EXEMPLARY, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL
45
+ DAMAGES OF ANY KIND, IN CONTRACT OR IN TORT, IN CONNECTION WITH THIS DOCUMENT
46
+ OR THE INFORMATION CONTAINED HEREIN, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH
47
+ LOSS OR DAMAGE.
48
+
49
+ All company, brand and product names in this document may be trademarks that
50
+ are the sole property of their respective owners.
51
+
52
+ This notice and disclaimer must be included on all copies of this document.
53
+
54
+ Connectivity Standards Alliance
55
+ 508 Second Street, Suite 206
56
+ Davis, CA 95616, USA
57
+
58
+ :xrefstyle: short
59
+ -->
60
+ <cluster xmlns : xsi =" http://www.w3.org/2001/XMLSchema-instance" xsi : schemaLocation =" types types.xsd cluster cluster.xsd" id =" 0x0B06" name =" Meter Identification Cluster" revision =" 1" >
61
+ <revisionHistory >
62
+ <revision revision =" 1" summary =" Initial version" />
63
+ </revisionHistory >
64
+ <clusterIds >
65
+ <clusterId id =" 0x0B06" name =" Meter Identification" />
66
+ </clusterIds >
67
+ <classification hierarchy =" base" role =" application" picsCode =" MTRID" scope =" Endpoint" />
68
+ <features >
69
+ <feature bit =" 0" code =" PWRTHLD" name =" PowerThreshold" summary =" Supports information about power threshold" >
70
+ <optionalConform />
71
+ </feature >
72
+ </features >
73
+ <dataTypes >
74
+ <enum name =" MeterTypeEnum" >
75
+ <item value =" 0x00" name =" Utility" summary =" Utility Meter" >
76
+ <mandatoryConform />
77
+ </item >
78
+ <item value =" 0x01" name =" Private" summary =" Private Meter" >
79
+ <mandatoryConform />
80
+ </item >
81
+ <item value =" 0x02" name =" Generic" summary =" Generic Meter" >
82
+ <mandatoryConform />
83
+ </item >
84
+ </enum >
85
+ <enum name =" PowerThresholdSourceEnum" >
86
+ <item value =" 0x00" name =" Contract" summary =" The value comes from a signed contract" >
87
+ <mandatoryConform />
88
+ </item >
89
+ <item value =" 0x01" name =" Regulator" summary =" The value comes from a legal regulator" >
90
+ <mandatoryConform />
91
+ </item >
92
+ <item value =" 0x02" name =" Equipment" summary =" The value comes from a certified limits of the meter" >
93
+ <mandatoryConform />
94
+ </item >
95
+ </enum >
96
+ </dataTypes >
97
+ <attributes >
98
+ <attribute id =" 0x0000" name =" MeterType" type =" MeterTypeEnum" default =" null" >
99
+ <access read =" true" readPrivilege =" view" />
100
+ <quality changeOmitted =" false" nullable =" true" scene =" false" persistence =" volatile" reportable =" false" sourceAttribution =" false" quieterReporting =" false" />
101
+ <mandatoryConform />
102
+ </attribute >
103
+ <attribute id =" 0x0001" name =" UtilityName" type =" string" default =" null" >
104
+ <access read =" true" readPrivilege =" view" />
105
+ <quality changeOmitted =" false" nullable =" true" scene =" false" persistence =" volatile" reportable =" false" sourceAttribution =" false" quieterReporting =" false" />
106
+ <mandatoryConform />
107
+ <constraint type =" maxLength" value =" 16" />
108
+ </attribute >
109
+ <attribute id =" 0x0002" name =" PointOfDelivery" type =" string" default =" null" >
110
+ <access read =" true" readPrivilege =" view" />
111
+ <quality changeOmitted =" false" nullable =" true" scene =" false" persistence =" volatile" reportable =" false" sourceAttribution =" false" quieterReporting =" false" />
112
+ <mandatoryConform />
113
+ <constraint type =" maxLength" value =" 16" />
114
+ </attribute >
115
+ <attribute id =" 0x0003" name =" PowerThreshold" type =" power-mW" default =" null" >
116
+ <access read =" true" readPrivilege =" view" />
117
+ <quality changeOmitted =" false" nullable =" true" scene =" false" persistence =" volatile" reportable =" false" sourceAttribution =" false" quieterReporting =" false" />
118
+ <mandatoryConform >
119
+ <feature name =" PWRTHLD" />
120
+ </mandatoryConform >
121
+ </attribute >
122
+ <attribute id =" 0x0004" name =" PowerThresholdSource" type =" PowerThresholdSourceEnum" default =" null" >
123
+ <access read =" true" readPrivilege =" view" />
124
+ <quality changeOmitted =" false" nullable =" true" scene =" false" persistence =" volatile" reportable =" false" sourceAttribution =" false" quieterReporting =" false" />
125
+ <mandatoryConform >
126
+ <feature name =" PWRTHLD" />
127
+ </mandatoryConform >
128
+ </attribute >
129
+ </attributes >
130
+ </cluster >
0 commit comments