-
Notifications
You must be signed in to change notification settings - Fork 4
/
Copy pathtl_node_gateway.ini
360 lines (355 loc) · 24.8 KB
/
tl_node_gateway.ini
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
[SET]
vidpid=248a08d0
prnid=08d4
log_backup=0
json_backup=0
ExtendAdvOption=0
CMD-----------------------mesh_bulk_cmd_debug=====================================================
;take "CMD-g_on =a3 ff 00 00 00 00 00 00 ff ff 82 02 01 00" as example
; flag("a3 ff": means master dongle mode; "e8 ff" means gateway mode)
; netkey_index("00 00": auto fill)
; appkey_index("00 00": auto fill)
; reliable retry count("00": depend on control box "retry" with 2 as default value; "ff": means reliable retry count is 0)
; reliable rsp_max("00": 00 is same with 01)
; dstitation address("ff ff": )
; opcode + par ("82 02 01 00": SIG opcode is 1 byte or 2 bytes)
CMD-LPN_get_level =e8 ff 00 00 00 00 ff 00 04 00 82 05
CMD-LPN_get_onoff =e8 ff 00 00 00 00 ff 00 04 00 82 01
CMD-lightness_get_Panel =e8 ff 00 00 00 00 00 00 ff ff 82 01
CMD----Note:retry count field of LPN distrib start is changed to timeout=============================
CMD-LPN_fw_distrib_ota_start_04 =e8 ff 00 00 00 00 32 00 01 00 83 19 00 00 04 00
CMD-----------------------------=
CMD-CDTP_OTS_GATT_ADV_ON =e9 ff 21 55 01 00 01
CMD-CDTP_OTS_GATT_ADV_OFF =e9 ff 21 55 01 00 00
CMD-----------------------------=
CMD-fw_update_info_get =e8 ff 00 00 00 00 00 00 02 00 83 08 00 01
CMD-fw_update_info_get_all =e8 ff 00 00 00 00 00 00 01 00 83 19 ff ff
CMD-fw_distribution_get =e8 ff 00 00 00 00 00 00 01 00 83 18
CMD----Note:these distribution start not for LPN. For LPN, please use LPN_fw_distrib_ota_start=======
CMD-fw_distribution_start_all =e8 ff 00 00 00 00 00 00 01 00 83 19 00 c0
CMD-fw_distribution_start_0002 =e8 ff 00 00 00 00 00 00 01 00 83 19 00 c0 02 00
CMD-fw_distribution_start_02_04 =e8 ff 00 00 00 00 00 00 01 00 83 19 00 c0 02 00 04 00
CMD-fw_distribution_start_0001 =e8 ff 00 00 00 00 00 00 01 00 83 19 00 c0 01 00
CMD------------------------distribution start end=================================================
CMD-fw_distribution_suspend =e8 ff 00 00 00 00 00 00 01 00 83 1a
CMD-fw_distribution_cancel =e8 ff 00 00 00 00 00 00 01 00 83 1b
CMD-fw_update_metadata_check =e8 ff 00 00 00 00 00 00 02 00 83 0a 00 01 02 03 04
CMD-fw_update_get =e8 ff 00 00 00 00 00 00 02 00 83 0c
CMD-fw_update_start =e8 ff 00 00 00 00 00 00 02 00 83 0d ff 00 00 11 22 33 44 55 66 77 88 00 01 02 03 04
CMD-fw_update_cancel =e8 ff 00 00 00 00 00 00 02 00 83 0e
CMD-fw_update_apply =e8 ff 00 00 00 00 00 00 02 00 83 0f
CMD-blob_transfer_get =e8 ff 00 00 00 00 00 00 02 00 83 00
CMD-blob_transfer_start =e8 ff 00 00 00 00 00 00 02 00 83 01 01 11 22 33 44 55 66 77 88 12 00 00 00 08 7c 01
CMD-blob_transfer_cancel =e8 ff 00 00 00 00 00 00 02 00 83 02 11 22 33 44 55 66 77 88
CMD-blob_block_start =e8 ff 00 00 00 00 00 00 02 00 83 04 11 22 33 44 55 66 77 88 00 00 10 00 00 8e 91 f1 68 12 00
CMD-blob_chunk_transfer =e8 ff 00 00 00 00 00 00 00 c0 66 00 00 01 02 03 04 05 06 07 08 09 0a 0b 0c 0d 0e 0f 10 11 12
CMD-blob_block_get =e8 ff 00 00 00 00 00 00 02 00 83 05
CMD-blob_info_get =e8 ff 00 00 00 00 00 00 02 00 83 06
CMD-----------------------------=
CMD-scheduler_get =e8 ff 00 00 00 00 00 00 02 00 82 49
CMD-sched_action_get =e8 ff 00 00 00 00 00 00 02 00 82 48 00
CMD-sched_action_set_off =e8 ff 00 00 00 00 00 00 02 00 60 40 06 00 80 80 02 00 00 00 00
CMD-sched_action_set_on =e8 ff 00 00 00 00 00 00 02 00 60 41 06 00 80 00 04 10 00 00 00
CMD-sched_action_set_scene1 =e8 ff 00 00 00 00 00 00 02 00 60 42 06 00 80 00 06 20 00 01 00
CMD-----------------------------=
CMD-time_set =e8 ff 00 00 00 00 00 00 02 00 5c 01 00 00 00 00 00 00 00 00 60
CMD-time_get =e8 ff 00 00 00 00 00 00 02 00 82 37
CMD-time_zone_set =e8 ff 00 00 00 00 00 00 02 00 82 3c 08 00 00 66 00 00
CMD-time_zone_get =e8 ff 00 00 00 00 00 00 02 00 82 3b
CMD-time_delta_set =e8 ff 00 00 00 00 00 00 02 00 82 3f 77 00 00 00 66 00 00
CMD-time_delta_get =e8 ff 00 00 00 00 00 00 02 00 82 3e
CMD-time_role_set =e8 ff 00 00 00 00 00 00 02 00 82 39 01
CMD-time_role_get =e8 ff 00 00 00 00 00 00 02 00 82 38
CMD-----------------------------=
CMD-scene_store =e8 ff 00 00 00 00 00 00 02 00 82 46 01 00
CMD-scene_del =e8 ff 00 00 00 00 00 00 02 00 82 9e 01 00
CMD-scene_reg_get =e8 ff 00 00 00 00 00 00 02 00 82 44
CMD-scene_recall =e8 ff 00 00 00 00 00 00 02 00 82 42 01 00 00 45 00
CMD-scene_get =e8 ff 00 00 00 00 00 00 02 00 82 41
CMD-----------------------------=
CMD-g_def_trans_time_set =e8 ff 00 00 00 00 00 00 02 00 82 0e 45
CMD-g_def_trans_time_get =e8 ff 00 00 00 00 00 00 02 00 82 0d
CMD-g_onpowerup_set =e8 ff 00 00 00 00 00 00 02 00 82 13 01
CMD-g_onpowerup_get =e8 ff 00 00 00 00 00 00 02 00 82 11
CMD-g_power_level_0001 =e8 ff 00 00 00 00 00 00 02 00 82 16 01 00 00
CMD-g_power_level_ffff =e8 ff 00 00 00 00 00 00 02 00 82 16 ff ff 00
CMD-g_power_level_get =e8 ff 00 00 00 00 00 00 02 00 82 15
CMD-g_power_level_last_get =e8 ff 00 00 00 00 00 00 02 00 82 19
CMD-g_power_level_range_set =e8 ff 00 00 00 00 00 00 02 00 82 21 01 00 ff ff
CMD-g_power_level_range_get =e8 ff 00 00 00 00 00 00 02 00 82 1d
CMD-g_power_level_def_set =e8 ff 00 00 00 00 00 00 02 00 82 1f ff ff
CMD-g_power_level_def_get =e8 ff 00 00 00 00 00 00 02 00 82 1b
CMD-----------------------------=
CMD-light_lc_mode_set =e8 ff 00 00 00 00 00 00 02 00 82 92 01
CMD-light_lc_mode_get =e8 ff 00 00 00 00 00 00 02 00 82 91
CMD-light_lc_om_set =e8 ff 00 00 00 00 00 00 02 00 82 96 01
CMD-light_lc_om_get =e8 ff 00 00 00 00 00 00 02 00 82 95
CMD-light_lc_onoff_set =e8 ff 00 00 00 00 00 00 02 00 82 9a 01 00
CMD-light_lc_onoff_get =e8 ff 00 00 00 00 00 00 02 00 82 99
CMD-sensor_occupancy_0 =e8 ff 00 00 00 00 00 00 02 00 52 01 42 00 00
CMD-sensor_occupancy_64 =e8 ff 00 00 00 00 00 00 02 00 52 01 42 00 64
CMD-light_lc_prop_set =e8 ff 00 00 00 00 00 00 02 00 62 2e 00 00 a0
CMD-light_lc_prop_get =e8 ff 00 00 00 00 00 00 02 00 82 9d 2e 00
CMD-----------------------------=
CMD-cfg_pub_set_sensor =e8 ff 00 00 00 00 00 00 04 00 03 04 00 ff ff 00 00 ff 00 15 00 11
CMD-----------------------------=
CMD-light_xyl_set =e8 ff 00 00 00 00 00 00 02 00 82 84 01 00 00 50 00 80 00
CMD-light_xyl_get =e8 ff 00 00 00 00 00 00 02 00 82 83
CMD-light_xyl_target_get =e8 ff 00 00 00 00 00 00 02 00 82 87
CMD-light_xyl_def_set =e8 ff 00 00 00 00 00 00 02 00 82 8d ff ff ff ff ff ff
CMD-light_xyl_def_get =e8 ff 00 00 00 00 00 00 02 00 82 89
CMD-light_xyl_range_set =e8 ff 00 00 00 00 00 00 02 00 82 8f 00 00 ff ff 00 00 ff ff
CMD-light_xyl_range_get =e8 ff 00 00 00 00 00 00 02 00 82 8b
CMD-----------------------------=
CMD-light_hsl_set =e8 ff 00 00 00 00 00 00 ff ff 82 76 00 20 00 50 00 80 00
CMD-light_hsl_get =e8 ff 00 00 00 00 00 00 ff ff 82 6d
CMD-light_hsl_target_get =e8 ff 00 00 00 00 00 00 ff ff 82 79
CMD-light_hue_set =e8 ff 00 00 00 00 00 00 ff ff 82 6f 00 50 00
CMD-light_hue_get =e8 ff 00 00 00 00 00 00 ff ff 82 6e
CMD-light_sat_set =e8 ff 00 00 00 00 00 00 ff ff 82 73 00 80 00
CMD-light_sat_get =e8 ff 00 00 00 00 00 00 ff ff 82 72
CMD-light_hsl_def_set =e8 ff 00 00 00 00 00 00 ff ff 82 7f ff ff ff ff ff ff
CMD-light_hsl_def_get =e8 ff 00 00 00 00 00 00 ff ff 82 7b
CMD-light_hsl_range_set =e8 ff 00 00 00 00 00 00 ff ff 82 81 00 00 ff ff 00 00 ff ff
CMD-light_hsl_range_get =e8 ff 00 00 00 00 00 00 ff ff 82 7d
CMD-----------------------------=
CMD-lightness_range_set =e8 ff 00 00 00 00 00 00 ff ff 82 5b 01 00 ff ff
CMD-lightness_range_get =e8 ff 00 00 00 00 00 00 ff ff 82 57
CMD-lightness_def_set =e8 ff 00 00 00 00 00 00 ff ff 82 59 ff ff
CMD-lightness_def_get =e8 ff 00 00 00 00 00 00 ff ff 82 55
CMD-lightness_linear_0001 =e8 ff 00 00 00 00 00 00 ff ff 82 50 01 00 00
CMD-lightness_linear_ffff =e8 ff 00 00 00 00 00 00 ff ff 82 50 ff ff 00
CMD-lightness_linear_get =e8 ff 00 00 00 00 00 00 ff ff 82 4f
CMD-light_ctl_set =e8 ff 00 00 00 00 00 00 ff ff 82 5e 01 00 20 4e 00 00 00
CMD-light_ctl_get =e8 ff 00 00 00 00 00 00 ff ff 82 5d
CMD-light_ctl_def_set =e8 ff 00 00 00 00 00 00 ff ff 82 69 ff ff 20 4e ff 7f
CMD-light_ctl_def_get =e8 ff 00 00 00 00 00 00 ff ff 82 67
CMD-light_ctl_temp_set =e8 ff 00 00 00 00 00 00 ff ff 82 64 20 4e 00 00 00
CMD-light_ctl_temp_get =e8 ff 00 00 00 00 00 00 ff ff 82 61
CMD-light_ctl_temp_range_set =e8 ff 00 00 00 00 00 00 ff ff 82 6b 20 03 20 4e
CMD-light_ctl_temp_range_get =e8 ff 00 00 00 00 00 00 ff ff 82 62
CMD-lightness_0000 =e8 ff 00 00 00 00 00 00 ff ff 82 4c 00 00 00
CMD-lightness_0001 =e8 ff 00 00 00 00 00 00 ff ff 82 4c 01 00 00
CMD-lightness_ffff =e8 ff 00 00 00 00 00 00 ff ff 82 4c ff ff 00
CMD-lightness_get =e8 ff 00 00 00 00 00 00 ff ff 82 4b
CMD-lightness_last_get =e8 ff 00 00 00 00 00 00 ff ff 82 53
CMD-g_level =e8 ff 00 00 00 00 00 00 02 00 82 06 00 00 00
CMD-g_level2 =e8 ff 00 00 00 00 00 00 02 00 82 06 34 12 00 45 ff
CMD-g_level_delta =e8 ff 00 00 00 00 00 00 02 00 82 09 00 06 00 00 00 54 05
CMD-g_level_move_plus =e8 ff 00 00 00 00 00 00 02 00 82 0B 00 40 00 41 00
CMD-g_level_move_minus =e8 ff 00 00 00 00 00 00 02 00 82 0B 00 c0 00 41 00
CMD-g_level_get =e8 ff 00 00 00 00 00 00 ff ff 82 05
CMD-g_level_get_02 =e8 ff 00 00 00 00 00 00 02 00 82 05
CMD-g_level_get_03 =e8 ff 00 00 00 00 00 00 03 00 82 05
CMD-g_level_set_02_8000 =e8 ff 00 00 00 00 00 00 02 00 82 06 00 88 00
CMD-g_level_set_02_8800 =e8 ff 00 00 00 00 00 00 02 00 82 06 00 88 00
CMD-g_level_set_02_b800 =e8 ff 00 00 00 00 00 00 02 00 82 06 00 b8 00
CMD-g_level_set_03_8800 =e8 ff 00 00 00 00 00 00 03 00 82 06 00 88 00
CMD-g_level_set_03_b800 =e8 ff 00 00 00 00 00 00 03 00 82 06 00 b8 00
CMD-----------------------------=
CMD-g_on =e8 ff 00 00 00 00 00 00 ff ff 82 02 01 00
CMD-g_off =e8 ff 00 00 00 00 00 00 ff ff 82 02 00 00
CMD-g_onoff_trans_1 =e8 ff 00 00 00 00 00 00 ff ff 82 02 01 00 45 ff
CMD-g_onoff_trans_0 =e8 ff 00 00 00 00 00 00 ff ff 82 02 00 00 45 ff
CMD-g_onoff_get =e8 ff 00 00 00 00 00 00 ff ff 82 01
CMD-----------------------------remote provision===========================
CMD-remote_prov_capa_get =e8 ff 00 00 00 00 02 01 02 00 80 4f
CMD-remote_prov_scan_get =e8 ff 00 00 00 00 02 01 02 00 80 51
CMD-remote_prov_scan_start =e8 ff 00 00 00 00 02 01 02 00 80 52 00 0a
CMD-remote_prov_scan_stop =e8 ff 00 00 00 00 02 01 02 00 80 53
CMD-remote_prov_link_get =e8 ff 00 00 00 00 02 01 02 00 80 58
CMD-remote_prov_link_open =e8 ff 00 00 00 00 02 01 02 00 80 59 79 8c 3c 25 f3 91 21 35 88 e5 b3 17 51 96 fa a4
CMD-remote_prov_link_close =e8 ff 00 00 00 00 02 01 02 00 80 5a 00
CMD-----------------------------=
CMD-cfg_node_identity_get =e8 ff 00 00 00 00 00 00 02 00 80 46 00 00
CMD-cfg_node_identity_set =e8 ff 00 00 00 00 00 00 02 00 80 47 00 00 01
CMD-----------------------------=
CMD-cfg_nk_update_000 =e8 ff 00 00 00 00 00 00 02 00 80 45 00 00 c0 c1 c2 c3 c4 c5 c6 c7 c8 c9 ca cb cc cd ce 00
CMD-cfg_key_phase_get =e8 ff 00 00 00 00 00 00 02 00 80 15 00 00
CMD-cfg_key_phase_set2 =e8 ff 00 00 00 00 00 00 02 00 80 16 00 00 02
CMD-cfg_key_phase_set3 =e8 ff 00 00 00 00 00 00 02 00 80 16 00 00 03
CMD-cfg_nk_update_Nd_000 =e8 ff 00 00 00 00 00 00 02 00 80 45 00 00 c0 c1 c2 c3 c4 c5 c6 c7 c8 c9 ca cb cc cd ce 00
CMD-cfg_key_phase_Nd_get =e8 ff 00 00 00 00 00 00 02 00 80 15 00 00
CMD-cfg_key_phase_Nd_set2 =e8 ff 00 00 00 00 00 00 02 00 80 16 00 00 02
CMD-cfg_key_phase_Nd_set3 =e8 ff 00 00 00 00 00 00 02 00 80 16 00 00 03
CMD-----------------------------=
CMD-cfg_netkey_add_fff =e8 ff 00 00 00 00 00 00 02 00 80 40 ff 0f b0 b1 b2 b3 b4 b5 b6 b7 b8 b9 ba bb bc bd be bf
CMD-cfg_netkey_update_fff =e8 ff 00 00 00 00 00 00 02 00 80 45 ff 0f c0 c1 c2 c3 c4 c5 c6 c7 c8 c9 ca cb cc cd ce cf
CMD-cfg_netkey_del_fff =e8 ff 00 00 00 00 00 00 02 00 80 41 ff 0f
CMD-cfg_ak_add_fff_eee =e8 ff 00 00 00 00 00 00 02 00 00 ff ef ee a0 a1 a2 a3 a4 a5 a6 a7 a8 a9 aa ab ac ad ae 09
CMD-cfg_ak_del_fff_eee =e8 ff 00 00 00 00 00 00 02 00 80 00 ff ef ee
CMD-cfg_ak_bind_fff_eee =e8 ff 00 00 00 00 00 00 02 00 80 3d 02 00 ee 0e 00 10
CMD-cfg_netkey_get =e8 ff 00 00 00 00 00 00 02 00 80 42
CMD-cfg_netkey_add_000 =e8 ff 00 00 00 00 00 00 02 00 80 40 00 00 b0 b1 b2 b3 b4 b5 b6 b7 b8 b9 ba bb bc bd be 00
CMD-cfg_netkey_update_000 =e8 ff 00 00 00 00 00 00 02 00 80 45 00 00 c0 c1 c2 c3 c4 c5 c6 c7 c8 c9 ca cb cc cd ce 00
CMD-cfg_netkey_del_000 =e8 ff 00 00 00 00 00 00 02 00 80 41 00 00
CMD-----------------------------=
CMD-cfg_appkey_add_001 =e8 ff 00 00 00 00 00 00 02 00 00 00 10 00 a0 a1 a2 a3 a4 a5 a6 a7 a8 a9 aa ab ac ad ae af
CMD-cfg_appkey_update_001 =e8 ff 00 00 00 00 00 00 02 00 01 00 10 00 e0 e1 e2 e3 e4 e5 e6 e7 e8 e9 ea eb ec ed ee ef
CMD-cfg_appkey_del_001 =e8 ff 00 00 00 00 00 00 02 00 80 00 00 10 00
CMD-cfg_appkey_bind_001 =e8 ff 00 00 00 00 00 00 02 00 80 3d 01 00 01 00 00 10
CMD-cfg_appkey_unbind_001 =e8 ff 00 00 00 00 00 00 02 00 80 3f 01 00 01 00 00 10
CMD-cfg_appkey_get =e8 ff 00 00 00 00 00 00 02 00 80 01 00 00
CMD-cfg_appkey_add_088 =e8 ff 00 00 00 00 00 00 02 00 00 00 80 08 63 96 47 71 73 4f bd 76 e3 b4 05 19 d1 d9 4a 48
CMD-cfg_appkey_update_088 =e8 ff 00 00 00 00 00 00 02 00 01 00 80 08 f0 f1 f2 f3 f4 f5 f6 f7 f8 f9 fa fb fc fd fe ff
CMD-cfg_appkey_del_088 =e8 ff 00 00 00 00 00 00 02 00 80 00 00 80 08
CMD-cfg_appkey_bind_088 =e8 ff 00 00 00 00 00 00 02 00 80 3d 01 00 88 00 00 10
CMD-cfg_appkey_unbind_088 =e8 ff 00 00 00 00 00 00 02 00 80 3f 01 00 88 00 00 10
CMD-cfg_model_appkey_get =e8 ff 00 00 00 00 00 00 02 00 80 4b 01 00 00 10
CMD-----------------------------=
CMD-cfg_pub_get_sig =e8 ff 00 00 00 00 00 00 02 00 80 18 02 00 00 10
CMD-cfg_pub_set_sig =e8 ff 00 00 00 00 00 00 02 00 03 02 00 01 00 00 00 ff 00 15 00 10
CMD-cfg_pub_set_sig_2s =e8 ff 00 00 00 00 00 00 02 00 03 02 00 01 00 00 00 ff 14 15 00 10
CMD-----------------------------=
CMD-cfg_pub_get_sig0015 =e8 ff 00 00 00 00 00 00 15 00 80 18 15 00 00 10
CMD-cfg_pub_set_sig0015 =e8 ff 00 00 00 00 00 00 15 00 03 15 00 01 00 00 00 ff 00 15 00 10
CMD-cfg_pub_set_sig0015_2s =e8 ff 00 00 00 00 00 00 15 00 03 15 00 01 00 00 00 ff 14 15 00 10
CMD-----------------------------=
CMD-cfg_pub_uuid_set =e8 ff 00 00 00 00 00 01 02 00 80 1a 02 00 01 02 03 04 05 06 07 08 09 0a 0b 0c 0d 0e 0f 10 00 00 00 00 00 00 10
CMD-----------------------------=
CMD-cfg_sub_add =e8 ff 00 00 00 00 00 01 02 00 80 1b 02 00 01 c0 00 10
CMD-cfg_sub_add_vendor =e8 ff 00 00 00 00 00 01 02 00 80 1b 02 00 01 c0 11 02 00 00
CMD-cfg_sub_del =e8 ff 00 00 00 00 00 01 02 00 80 1c 02 00 01 c0 00 10
CMD-cfg_sub_ov =e8 ff 00 00 00 00 00 01 02 00 80 1e 02 00 01 c0 00 10
CMD-cfg_sub_del_all =e8 ff 00 00 00 00 00 01 02 00 80 1d 02 00 00 10
CMD-cfg_sub_uuid_add =e8 ff 00 00 00 00 00 01 02 00 80 20 02 00 01 02 03 04 05 06 07 08 09 0a 0b 0c 0d 0e 0f 10 00 10
CMD-cfg_sub_uuid_del =e8 ff 00 00 00 00 00 01 02 00 80 21 02 00 01 02 03 04 05 06 07 08 09 0a 0b 0c 0d 0e 0f 10 00 10
CMD-cfg_sub_uuid_ow =e8 ff 00 00 00 00 00 01 02 00 80 22 02 00 01 02 03 04 05 06 07 08 09 0a 0b 0c 0d 0e 0f 10 00 10
CMD-----------------------------=
CMD-health_fault_clear =e8 ff 00 00 00 00 00 00 55 00 80 2f 02 11
CMD-health_fault_clear_noack =e8 ff 00 00 00 00 00 00 55 00 80 30 02 11
CMD-health_fault_get =e8 ff 00 00 00 00 00 00 55 00 80 31 02 11
CMD-health_fault_test =e8 ff 00 00 00 00 00 00 55 00 80 32 01 02 11
CMD-health_fault_test_noack =e8 ff 00 00 00 00 00 00 55 00 80 33 01 02 11
CMD-health_period_get =e8 ff 00 00 00 00 00 00 55 00 80 34
CMD-health_period_set =e8 ff 00 00 00 00 00 00 55 00 80 35 01
CMD-health_period_set_noack =e8 ff 00 00 00 00 00 00 55 00 80 36 01
CMD-----------------------------=
CMD-cfg_hb_pub_get_sig =e8 ff 00 00 00 00 00 00 02 00 80 38
CMD-cfg_hb_pub_set_sig =e8 ff 00 00 00 00 00 00 02 00 80 39 01 00 ff 02 05 07 00 00 00
CMD-cfg_hb_sub_get_sig =e8 ff 00 00 00 00 00 00 02 00 80 3a
;CMD-cfg_hb_sub_set_sig =e8 ff 00 00 00 00 00 00 02 00 80 3b 00 00 00 00 00
CMD-----------------------------test segment===========================
CMD-g_mac_on_unrel_test_seg =e8 ff 00 00 00 00 00 00 02 00 82 03 01 00 01 02 03 04 05 06 07 08 09 0a 0b 0c 0d 0e 0f
CMD-g_mac_off_unrel_test_seg =e8 ff 00 00 00 00 00 00 02 00 82 03 00 00 01 02 03 04 05 06 07 08 09 0a 0b 0c 0d 0e 0f
CMD-g_mac_on_rel_test_seg =e8 ff 00 00 00 00 00 00 02 00 82 02 01 00 01 02 03 04 05 06 07 08 09 0a 0b 0c 0d 0e 0f
CMD-g_mac_off_rel_test_seg =e8 ff 00 00 00 00 00 00 02 00 82 02 00 00 01 02 03 04 05 06 07 08 09 0a 0b 0c 0d 0e 0f
CMD-----------------------------vendor command format======
; op cid__
; op_rsp(00 means no response, just use internal, will not sent to slave)
; tid_pos(00 means no tid, tid position = n - 1, such as 01 means the least byte, just use internal, will not sent to slave)
; par__________________________
CMD-vendor_on =e8 ff 00 00 00 00 00 00 ff ff c2 11 02 c4 02 01 00
CMD-vendor_off =e8 ff 00 00 00 00 00 00 ff ff c2 11 02 c4 02 00 00
CMD-vendor_on_noack =e8 ff 00 00 00 00 00 00 ff ff c3 11 02 00 02 01 00
CMD-vendor_off_noack =e8 ff 00 00 00 00 00 00 ff ff c3 11 02 00 02 00 00
CMD-vendor_onoff_get =e8 ff 00 00 00 00 00 00 ff ff c1 11 02 c4 00
CMD-vd_group_g_sub_op_user_set =e8 ff 00 00 00 00 00 00 ff ff c2 11 02 c4 00 80 01
CMD-vd_group_g_sub_op_user_set_noack =e8 ff 00 00 00 00 00 00 ff ff c2 11 02 00 00 80 01
CMD-vd_group_g_sub_op_user_get =e8 ff 00 00 00 00 00 00 ff ff c1 11 02 c4 00 80
CMD-vd_mesh_user_demo_set =e8 ff 00 00 00 00 00 00 ff ff e0 11 02 e3 00 01
CMD-vd_mesh_user_demo_set_noack =e8 ff 00 00 00 00 00 00 ff ff e2 11 02 00 00 01
CMD-vd_mesh_user_demo_get =e8 ff 00 00 00 00 00 00 ff ff e1 11 02 e3 00
CMD-vendor_lpn_gatt_ota_en =e8 ff 00 00 00 00 00 00 04 00 c2 11 02 c4 00 02 01
CMD-vendor_lpn_gatt_ota_dis =e8 ff 00 00 00 00 00 00 04 00 c2 11 02 c4 00 02 00
CMD-vendor_lpn_gatt_ota_get =e8 ff 00 00 00 00 00 00 04 00 c1 11 02 c4 00 02
CMD-vendor_sensor_get =e8 ff 00 00 00 00 00 00 04 00 e0 11 02 e1 00
CMD-----------------------------=
CMD-properties_user_get =e8 ff 00 00 00 00 00 00 02 00 82 2e
CMD-property_user_get =e8 ff 00 00 00 00 00 00 02 00 82 2f 4e 00
CMD-property_user_set_11 =e8 ff 00 00 00 00 00 00 02 00 4c 4e 00 11 11 11
CMD-property_user_set_22 =e8 ff 00 00 00 00 00 00 02 00 4c 4e 00 22 22 22
CMD-properties_admin_get =e8 ff 00 00 00 00 00 00 02 00 82 2c
CMD-property_admin_get =e8 ff 00 00 00 00 00 00 02 00 82 2d 4e 00
CMD-property_admin_set_33 =e8 ff 00 00 00 00 00 00 02 00 48 4e 00 03 33 33 33
CMD-property_admin_set_44 =e8 ff 00 00 00 00 00 00 02 00 48 4e 00 03 44 44 44
CMD-properties_mfg_get =e8 ff 00 00 00 00 00 00 02 00 82 2a
CMD-property_mfg_get =e8 ff 00 00 00 00 00 00 02 00 82 2b 4e 00
CMD-property_mfg_set_55 =e8 ff 00 00 00 00 00 00 02 00 44 4e 00 01
CMD-property_mfg_set_66 =e8 ff 00 00 00 00 00 00 02 00 44 4e 00 00
CMD-properties_client_get =e8 ff 00 00 00 00 00 00 02 00 4f 01 00
CMD------------------------------------ mesh command end================
CMD------------GW_NODE-PTS FD Client Test-----=
CMD-BV1_1_dist_receivers_get =e8 ff 00 00 00 00 00 00 01 00 83 14 00 00 10 00
CMD-BV1_2_dist_recv_del_all =e8 ff 00 00 00 00 00 00 01 00 83 12
CMD-BV1_3_dist_recv_add =e8 ff 00 00 00 00 00 00 01 00 83 11 01 00 00
CMD-BV2_fw_capabilities_get =e8 ff 00 00 00 00 00 00 01 00 83 16
CMD-BV3_1_dist_upload_start =e8 ff 00 00 00 00 00 00 01 00 83 1f ff ff ff 55 66 55 66 55 66 55 66 00 10 00 00 04 88 33 66 11 88 33 66 11
CMD-BV3_2_dist_upload_blob_tran =ac ff 01 00 00 00 01 00 01 00
CMD-BV3_3_blob_transfer_get =e8 ff 00 00 00 00 00 00 01 00 83 00
CMD-BV4_1_dist_update_info_get =e8 ff 00 00 00 00 00 00 64 00 83 08 00 01
CMD-BV4_2_dist_upload_oob_start =e8 ff 00 00 00 00 00 00 01 00 83 20 04 31 32 33 34 11 11 11 11
CMD-BV5_1_dist_upload_get =e8 ff 00 00 00 00 00 00 01 00 83 1e
CMD-BV5_2_dist_upload_cancel =e8 ff 00 00 00 00 00 00 01 00 83 21
CMD-BV6_1_dist_fw_get =e8 ff 00 00 00 00 00 00 01 00 83 23 ab ab ab ab
CMD-BV6_2_dist_fw_get_index =e8 ff 00 00 00 00 00 00 01 00 83 24 02 00
CMD-BV6_3_dist_fw_del =e8 ff 00 00 00 00 00 00 01 00 83 25 ab ab ab ab
CMD-BV6_4_dist_fw_del_all =e8 ff 00 00 00 00 00 00 01 00 83 26
CMD-BV7_1_dist_get =e8 ff 00 00 00 00 00 00 01 00 83 18
CMD-BV7_2_dist_start =e8 ff 00 00 00 00 00 00 01 00 83 19 ff ff ff ff ff 01 00 00 00 00
CMD-BV7_3_dist_apply =e8 ff 00 00 00 00 00 00 01 00 83 1c
CMD-BV8_1_dist_get =e8 ff 00 00 00 00 00 00 01 00 83 18
CMD-BV8_2_dist_cancel =e8 ff 00 00 00 00 00 00 01 00 83 0e
CMD-BV9_1_dist_suspend =e8 ff 00 00 00 00 00 00 01 00 83 1a
CMD-BV9_2_dist_start =e8 ff 00 00 00 00 00 00 01 00 83 19 ff ff ff ff ff 01 00 00 00 00
CMD------------GW_NODE-PTS FU Client Test-----=
CMD-BV1_1_fw_update_info_get =e8 ff 00 00 00 00 00 00 01 00 83 08 00 01
CMD-BV1_2_fw_metadata_check =e8 ff 00 00 00 00 00 00 01 00 83 0a 00 ab ab ab ab
CMD-BV2_1_fw_update_start =e8 ff 00 00 00 00 00 00 01 00 83 0d ff ff ff 11 22 33 44 55 66 77 88 00 01 02 03 04
CMD-BV2_2_fw_update_start =e8 ff 00 00 00 00 00 00 00 01 83 0d ff ff ff 11 22 33 44 55 66 77 88 00 01 02 03 04
CMD-BV2_3_fw_update_start =e8 ff 00 00 00 00 00 00 23 01 83 0d ff ff ff 11 22 33 44 55 66 77 88 00 01 02 03 04
CMD-BV2_4_update_blob_tran =ac ff 01 00 00 00 01 00 01 00
CMD-BV2_5_fw_update_apply =e8 ff 00 00 00 00 00 00 01 00 83 0f
CMD-BV3_1_fw_update_get =e8 ff 00 00 00 00 00 00 01 00 83 0c
CMD-BV3_2_fw_update_cancel =e8 ff 00 00 00 00 00 00 01 00 83 0e
CMD------------GW_NODE-PTS BT Client Test-----=
;Note: The selected firmware must be the same as the PTS's, and the transfer mode may need to change between push and mode for different PTS versions.
CMD-BV1_1_blob_transfer_flow =ac ff 01 00 00 00 01 00 01 00
CMD-BV2_1_blob_transfer_flow =ac ff 01 00 00 00 01 00 01 00
CMD-BV3_1_blob_info_get =e8 ff 00 00 00 00 00 00 01 00 83 06
CMD-BV3_2_blob_transfer_start =e8 ff 00 00 00 00 00 00 01 00 83 01 80 11 00 00 00 00 00 00 11 24 00 00 00 06 7c 01
CMD-BV3_3_blob_transfer_cancel =e8 ff 00 00 00 00 00 00 01 00 83 02 11 00 00 00 00 00 00 11
CMD-BV4_1_blob_info_get =e8 ff 00 00 00 00 00 00 01 00 83 06
CMD-BV4_2_blob_transf_start =e8 ff 00 00 00 00 00 00 01 00 83 01 80 11 00 00 00 00 00 00 11 24 00 00 00 06 7c 01
CMD-BV5_1_blob_info_get =e8 ff 00 00 00 00 00 00 01 00 83 06
CMD-BV5_2_blob_transf_start =e8 ff 00 00 00 00 00 00 01 00 83 01 80 11 00 00 00 00 00 00 11 24 00 00 00 06 7c 01
;BV6 need to wait PTS for 5 rounds timeout, totally takes about 5minus.
CMD-BV6_1_blob_transfer_flow =ac ff 01 00 00 00 01 00 01 00
CMD-BV7_1_blob_info_get =e8 ff 00 00 00 00 00 00 01 00 83 06
CMD-BV7_2_blob_info_get =e8 ff 00 00 00 00 00 00 65 00 83 01
CMD-BV7_3_blob_transf_start =e8 ff 00 00 00 00 00 00 01 00 83 01 40 11 00 00 00 00 00 00 11 24 00 00 00 06 7c 01
CMD-BV8_1_blob_transfer_get =e8 ff 00 00 00 00 00 00 01 00 83 00
CMD------------------------------------ PTS command end================
;4-byte: nn-hl-vvvv => nn: number of byte; hl: word[h:l] == nn
EVT-read_remote_version =02f00c04 010f0000 010f0000 020f0000 010f0000 020f0000 020f0000
EVT-cmd_complete_ok =02f00e04 010f0000 010f0000 020f0000 01700000
EVT-cmd_complete_fail =02f00e04 010f0000 010f0000 020f0000
EVT-cmd_status_ok =02f00f04 010f0000 01700000 010f0000 020f0000
EVT-cmd_status_fail =02f00f04 010f0000 010f0000 010f0000 020f0000
EVT-connection_complete =02f00304 010f0000 01700000 020f0000
EVT-connection_fail =02f00304 010f0000 010f0000 020f0000
EVT-disconn_complete =02f00504 010f0000 01700000 020f0000
EVT-le_conn_complete =02f03e04 010f0000 01700001 01700000 020f0000
EVT-le_conn_fail =02f03e04 010f0000 01700001 010f0000 020f0000
EVT-le_adv_report =02f03e04 010f0000 01700002 010f0000
EVT-le_conn_update =02f03e04 010f0000 01700003 010f0000 020f0000 020f0000 020f0000 020f0000
EVT-le_remote_feature =02f03e04 010f0000 01700004 010f0000 020f0000
EVT-le_ltk_request =02f03e04 010f0000 01700005 010f0000 020f0000
EVT-le_remote_parameter =02f03e04 010f0000 01700006 010f0000 020f0000
EVT-le_data_length_chg =02f03e04 010f0000 01700007 010f0000 020f0000
EVT-le_read_p256 =02f03e04 010f0000 01700008 010f0000
EVT-le_dhkey_complete =02f03e04 010f0000 01700009 010f0000
EVT-le_conn_enhance_ok =02f03e04 010f0000 0170000a 01700000 020f0000
EVT-le_conn_enhance_fail=02f03e04 010f0000 0170000a 010f0000 020f0000
EVT-le_direct_adv_report=02f03e04 010f0000 0170000b 010f0000
EVT-att_not_found_rsp =01700002 020f0000 020f0000 020f0000 02f00004 01700001
EVT-att_exchg_mtu_req =01700002 020f0000 020f0000 020f0000 02f00004 01700002
EVT-att_exchg_mtu_rsp =01700002 020f0000 020f0000 020f0000 02f00004 01700003
EVT-att_find_info_rsp =01700002 020f0000 020f0000 020f0000 02f00004 01700005
EVT-att_find_by_type_value_rsp =01700002 020f0000 020f0000 020f0000 02f00004 01700007
EVT-att_read_by_byte_rsp=01700002 020f0000 020f0000 020f0000 02f00004 01700009
EVT-att_read_rsp =01700002 020f0000 020f0000 020f0000 02f00004 0170000b
EVT-att_read_blob_rsp =01700002 020f0000 020f0000 020f0000 02f00004 0170000d
EVT-att_notify =01700002 020f0000 020f0000 020f0000 02f00004 0170001b 020f0000
EVT-conn_parameter_req =01700002 020f0000 020f0000 02f0000c 02f00005
EVT-spp_test_status =017000ff 010f0000 02f007e2 020f0000 020f0000 020f0000 020f0000