[Bug]: Growatt - MIN 3600TL-X unable to auto connect. #1216

Open
Cees-JanBerg opened this issue Jan 14, 2025 · 2 comments
Open

[Bug]: Growatt - MIN 3600TL-X unable to auto connect. #1216

Cees-JanBerg opened this issue Jan 14, 2025 · 2 comments
Labels
bug Something isn't working non solax non solax

Comments

@Cees-JanBerg
Copy link

Describe the bug

I have 3 Growatt inverters, 2 LT-XE and 1 LT-X. First I connected everything to an RS485 TO ETH (B) the 120Ohm resistors on both ends. This turned out not to be necessary and I removed it again, now I have 3.5Vdc on all connectors. After this I tried everything, without being able to connect to the LT-X inverter. In the end I loaded 1 inverter into the integration with address 01. After it was connected, I switched the plug to the inverter that wouldn't connect. I changed the address to 01 and I was connected. then loaded the other inverters at addresses 2 and 3 and everything works.

I have no idea why it didn't work, but I suspect something went wrong loading the registers. There could be a difference between the versions that prevents it from being found.

Integration Version

2025.01.7

Homeassistant core version

2025.1.2

Inverter brand

Growatt

Plugin used

plugin_growatt.py

Serial prefix

AK1.0/AKAA2001

Connection Method

RS485 TO ETH (B)

Detailed Error Log

No response

Additional context

No response

@Cees-JanBerg Cees-JanBerg added bug Something isn't working non solax non solax labels Jan 14, 2025
@wills106
Copy link
Owner

Try 2025.01.8 there was an issue with pyModbbus 3.8.3 in Integration 2025.01.7

@Cees-JanBerg
Copy link
Author

Thanks for the quick response,
I tried the new version, but the inverter no longer came online after this. After removing the integration I tried to configure it again. this doesn't work normally. it only works if I first load another inverter to the modbus address and then adjust the addresses in the inverter.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment